In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

ヘルスモニタレポート「 Redundant configuration is missing for cluster switches 」 .

Views:
3
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

環境

  • すべての FAS システム
  • スイッチクラスタ構成

問題

ヘルスアラートが生成さ れ、「クラスタスイッチの冗長構成がありません」と報告される。

 ::> system health alert show -alert-id ClusterSwitchMissing_Alert -instance Node: node1 Monitor: cluster-switch Alert ID: ClusterSwitchMissing_Alert Alerting Resource: cluster1-02 Subsystem: Switch-Health Indication Time: Wed Nov 27 10:22:08 2019 Perceived Severity: Major Probable Cause: Configuration_error Description: Redundant configuration is missing for cluster switches. Corrective Actions: 1) Ensure that a redundant pair of cluster switches exists in the network. 2) Ensure that cluster ports are connected to both switches. 3) Enable the Cisco Discovery Protocol (CDP)/Industy Standard Discovery Protocol(ISDP) on switches, if you previously disabled it. CDP/ISDP is enabled by default. Refer to your switch documentation for instructions. 4) If Data ONTAP cannot automatically discover a switch, use the "system cluster-switch create" command to configure discovery and monitoring of the switch. 

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support