メインコンテンツまでスキップ

PSUの障害が原因でノードからシステムヘルスアラートでCriticalPSUFruOffAlertが報告される

Views:
37
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • FAS / AFFシステム

問題

  • CriticalPSUFruOffAlert 健全性アラートのノードレポート:
ClusterA::> system health alert show -instance
            Node: Node-01
          Monitor: chassis
          Alert ID: CriticalPSUFruOffAlert
     Alerting Resource: xxxxxxx
         Subsystem: Environment
        Indication Time: Fri May 20 02:08:21 2022
             Severity: Critical
         Probable Cause: Loss_of_redundancy
           Description: PSU1 is off. The nodes in this chassis are Node-01, Node-02.
     Corrective Actions: 1. Check PSU1 and switch it on.
                     2. Refer to the Hardware specification guide for more information on the position of the                              power supply unit (PSU) and ways to check or replace it.
                     3. Contact support personnel if the alert persists.
  • イベントログでは、次のイベントが報告されます。

[Node-01: env_mgr: monitor.chassisPowerSupply.off:notice]: Chassis power supply 1 off.
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Temperature is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Current is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan1 Speed is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan1 Fault is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan2 Speed is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan2 Fault is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Pwr Out OK is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fault is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Over Temp is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Over Volt is Unreadable
[Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Over Curr is Unreadable

[Node-01: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU1.
[Node-01: power_low_monitor: callhome.chassis.power:error]: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1.

  • SPがPSUセンサーを na のように報告し system sensors ます。

SP Node-01> system sensors

Sensor Name    | Current   | Unit     | Status    | LCR     | LNC     | UNC     | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
PSU1_Present    | 0x0     | discrete   | Present   | na     | na     | na     | na     
PSU1_Temp     | na      | degrees C  | na      | 0.000    | 5.000    | 50.000   | 60.000   
PSU1_Curr     | na      | Amps     | na      | na     | na     | na     | na     
PSU1_Fan1_Speed  | na      | RPM     | na      | 4500.000  | 4600.000  | na     | na     
PSU1_Fan1_Fault  | na      | discrete   | na      | na     | na     | na     | na     
PSU1_Fan2_Speed  | na      | RPM     | na      | 4500.000  | 4600.000  | na     | na     
PSU1_Fan2_Fault  | na      | discrete   | na      | na     | na     | na     | na     
PSU1_Status_OK   | na      | discrete   | na      | na     | na     | na     | na     
PSU1_Pwr_In_OK   | 0x0     | discrete   | Deasserted | na     | na     | na     | na     
PSU1_Pwr_Out_OK  | na      | discrete   | na      | na     | na     | na     | na     
PSU1_Fault     | na      | discrete   | na      | na     | na     | na     | na     
PSU1_Input_Type  | na      | discrete   | na      | na     | na     | na     | na     
PSU1_Over_Temp   | na      | discrete   | na      | na     | na     | na     | na     
PSU1_Over_Volt   | na      | discrete   | na      | na     | na     | na     | na     
PSU1_Over_Curr   | na      | discrete   | na      | na     | na     | na     | na     

  • 影響を受けたPSUを取り付け直しても、問題が動作しない。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.