In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

サービスプロセッサの API サービスが応答しないため、コマンドがタイムアウトして AutoSupport が切り捨てられます

Views:
63
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

環境

  • FAS2720
  • FAS2750
  • ONTAP 9
  • Baseboard Management Controller(BMC)

問題

  1. プラットフォームサブシステムデータの AutoSupport 収集が 120 秒後にタイムアウトになります
cluster::*> system node autosupport manifest show -status *-limit -fields subsys,status,error,time-collected  -subsys !log_files -time-collected >120000
node           seq-num prio-num subsys   time-collected status error
-------------- ------- -------- -------- -------------- ------------------------------- -----
node-01       812     49      platform 125315         collection-truncated-time-limit
node-01       804     133      platform 125300        collection-truncated-time-limit
node-01       797     49       platform 125197         collection-truncated-time-limit
 
  1. system node power showsystem node environment sensors show コマンドは、 120 秒後に、およびタイムアウトします。
cluster::*> system node environment sensors show -node node-01

Warning: Unable to list entries on node node-01. The Service Processor on node "node-01" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again.

Error: show failed: The Service Processor on node "node-01" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again.
または
Warning: Unable to list entries on node node-01. SP API service is not available on node "node-01". 
    Check SP firmware version and Data Ontap(R) version.

Error: show failed: SP API service is not available on node
    "node-01". Check SP firmware version and Data Ontap(R) version.

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support