メインコンテンツまでスキップ

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

コントローラの障害が原因でBMCのファームウェアを更新できません

Views:
15
Visibility:
Public
Votes:
0
Category:
aff-series<a>FSE</a><a>2009062541</a>
Specialty:
hw
Last Updated:

環境

  • FAS/AFF
  • ONTAP 9
  • サービス プロセッサ(SP)
  • Baseboard Management Controller(BMC)

問題

  • SP / BMCファームウェアのアップグレードが失敗し、イベントログに次のエラーが報告されます。

[cluster1-01: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update from 10.5 to 10.6 has been triggered.'}
[cluster1-01: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP firmware image has been successfully transferred to SP using network interface.'}
[cluster1-01: servprocd: sp.servprocd.upd.unexpt.evts:debug]: params: {'reason': 'Unable to successfully update SP firmware using network interface'}
[cluster1-01: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.

  • SP-MGMT-MLOG-TXT.GZ AutoSupport からのレポートでは、SP / BMCに到達できないことが報告されます。

[kern_servprocd:info:7198] 0x808707100: 0: NOTICE: Servprocd::FTM: transferred /mroot/etc/RLM_FW/sp_image.tar.gz to sp://cluster1-01:/mnt/sapps/sp_image.tar.gz
[kern_servprocd:info:7198] 0x808707100: 0: NOTICE: Servprocd::SpUpdate: update: SP firmware image has been successfully transferred to SP using network interface.
[kern_servprocd:info:5642] 0x808702b00: 0: ERR: Servprocd::SpUpdate: writeImage: spcs sp update command failed (The Service Processor on node "cluster1-01" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again.)
[kern_servprocd:info:5642] 0x808702b00: 0: ERR: Servprocd::SpUpdate: update: unable to successfully update SP firmware using network interface

  • SP-LATEST-RUNTIME AutoSupport からのレポートMemFreeは57,000 KBを超えています

MemFree:       96968 kB

  • SP-LATEST-CONFIGURATION AutoSupport からは、N/A primaryおよびbackup firmware versionsを表示します。

version
=======
Booted primary firmware version 11.6
Primary firmware version N/A
Backup firmware version N/A

  • SP-LATEST-SYSLOG AutoSupport からの手動更新の試行時に、次のようなエラーが報告されます。

BMC fud_eth[29319]: get_notif_shm: Failed to create the shared memory key
BMC fud_eth[29319]: ipmi_notif_to_ontap: Unable to set progress state as shared memory is not accessible.
BMC fud_eth[29319]: Downloading package...
BMC fud_eth[29319]: system() returned ret1 = 0, ret2 = 0
BMC last message repeated 3 times
BMC fud_eth[29319]:  FW package download from ftp://anonymous@10.10.10.10/software//BMC_FW_308-04071_11.7.tar.gz failed.
BMC fud_eth[29319]: Cleaning up..

のとう