問題
CHSPWR:System Notification from Filer1 (CHASSIS POWER DEGRADED: PSU1 12V is failed. PSU1 5V is failed. PSU1 3V is failed)
System
Notification from Filer1 (CHASSIS POWER DEGRADED: PSU1 12V is failed. PSU1 5V is failed. PSU1 3V is failed)
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 AC Failed
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 12V Failed
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 5V Failed
[Filer1: monitor.chassisPower.degraded:notice]: Chassis power is degraded:
AutoSupport message: Chassis Power Degraded
次の AutoSupport メッセージが送信されます。
SHELF_FAULT
CHASSIS POWER SUPPLY FAIL
CHASSIS POWER SUPPLY DEGRADED
CHSPWR:
System
Notification from Filer1 (CHASSIS POWER DEGRADED: sensor RTC Battery) WARNING
トラブルシューティング
包括的な MB テストに失敗しました
ERROR ENV013858: sensor RTC Battery failed;
sensor failed to return to normal
measured: 2633mV; upperLimit: 3996mV; lowerLimit: 0mV;
FSE バッテリーを固定するクリップが曲がっています。今回は正常に診断を実行しました。
( RTC バッテリ) ...........2,800 < 3072 mV < 3500