AutoSupport メッセージ:シャーシの電力が低下しました
のしんだ
環境
- Data ONTAP 8.2.5 以前
 - Data ONTAP 7-Mode
 
問題
CHSPWR:System Notification from Filer1 (CHASSIS POWER DEGRADED: PSU1 12V is  failed. PSU1 5V is  failed. PSU1 3V is  failed)
System Notification from Filer1 (CHASSIS POWER DEGRADED: PSU1 12V is  failed. PSU1 5V is  failed. PSU1 3V is  failed)
[Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 AC Failed
 [Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 12V Failed
 [Filer1: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU 1 5V Failed
 [Filer1: monitor.chassisPower.degraded:notice]: Chassis power is degraded:
AutoSupport message: Chassis Power Degraded
次の AutoSupport メッセージが送信されます。
SHELF_FAULT
 CHASSIS POWER SUPPLY FAIL
 CHASSIS POWER SUPPLY DEGRADED
CHSPWR:System Notification from Filer1 (CHASSIS POWER DEGRADED:  sensor RTC Battery) WARNING
トラブルシューティング
包括的な MB テストに失敗しました
 ERROR ENV013858: sensor RTC Battery failed;
                  sensor failed to return to normal
                  measured: 2633mV; upperLimit: 3996mV; lowerLimit: 0mV;
FSE バッテリーを固定するクリップが曲がっています。今回は正常に診断を実行しました。
( RTC バッテリ) ...........2,800 < 3072 mV < 3500