Active IQ Unified Manager :クラスタデータソースを追加できません
環境
- Active IQ Unified Manager(AIQUM)
- ONTAP 9
問題
Active IQ Unified Managerに新しいクラスタを追加しようとすると、次のエラーメッセージが表示されます。
Unable to add cluster datasource. This can occur if the clocks
on the systems are not synchronized and the Active IQ Unified Manager HTTPS certificate start date is later than the date on the cluster, or if the cluster has reached the maximum number of EMS notification destinations.
server_acq.log
...
JJJJ-MM-DD hh:mm:ss,523 ERROR [default task-6] c.o.s.a.s.AcquisitionFacadeUtil (AcquisitionFacadeUtil.java:202) - failed to register EMS: : com.netapp.oci.netapp.client.interfaces.data.EmsManagerException: Failed to read the certificate due to incorrect formatting. (errno=61102)
...
JJJJ-MM-DD hh:mm:ss,532 ERROR [default task-6] c.n.s.a.s.r.s.i.AcquisitionFacadeSessionServiceImpl (AcquisitionFacadeSessionServiceImpl.java:813) - Fail to add data source for acquisitionUnitName: local, dataSourceName: <IP:NNN.NNN.NNN.NNN>, vendor:NetApp OCI Essentials, model: NetApp OCI Essentials, datasourceTypeId: 91, manual: 1, isActive: false, attrs: -- listing properties --
...
サーバ/ audit.log
...
Month. DD hh:mm:ss [:INFO]:<Server-Name>:API:in:[<IP:CCC.CCC.CCC.CCC>]::GET: Fetching cluster certificate for host <IP:NNN.NNN.NNN.NNN> over port 443
Month. DD hh:mm:ss [:INFO]:<Server-Name>:API:action:[<IP:CCC.CCC.CCC.CCC>]::Adding datasource host <IP:NNN.NNN.NNN.NNN>
...
Month. DD hh:mm:ss [:ERR]:<Server-Name>:API:action:[<IP:CCC.CCC.CCC.CCC>]::Unable to add cluster datasource. This can occur if the clocks on the systems are not synchronized and the Active IQ Unified Manager HTTPS certificate start date is later than the date on the cluster, or if the cluster has reached the maximum number of EMS notification destinations.
...