Unified Managerの監視が「Error:Data ONTAP reported error code(13130)、message:'upicate entry(エントリの複製)」というエラーで失敗します。
環境
- OnCommand Unified Manager(OCUM)9.5以降
- Active IQ Unified Manager (AIQUM)9.6x
問題
- 複数のクラスタで監視に失敗したことが報告されます
- Unified ManagerのWebインターフェイスに次のエラーが表示されます。
Monitoring failed for cluster clustername. Reason: Cluster cannot be reached. Ensure that there is network connectivity to the cluster and the API has not timed out. The following settings must also be configured correctly for the cluster: hostname or cluster-management IP address, protocol, and port. If the issue persists, contact technical support.
ocum-error.log
ファイルには次のエラーが含まれます。
メモ: ocum-error.log
ファイルを検索するには、ナレッジ記事:「 What are the 著しい log files and their 各 locations for Active IQ Unified Manager ?」
2022-02-17 14:40:50,191 ERROR [oncommand] [...] Failed to Configure EMS for Cluster cluster14367
2022-02-17 14:42:48,204 ERROR [oncommand] [...] Failed to create EMS Destination cluster24823.beta.local on cluster15423. Error: Data ONTAP reported error code (13130), message: 'duplicate entry' (request: '<ems-destination-create><name>cluster24823.beta.local</name><syslog><remote-ip>cluster24823.beta.local</remote-ip></syslog></ems-destination-create>').
2022-02-17 14:42:48,318 ERROR [oncommand] [...] Failed to create EMS Destination cluster24823.beta.local on cluster15423. Error: Data ONTAP reported error code (13130), message: 'duplicate entry' (request: '<ems-destination-create><name>cluster24823.beta.local</name><syslog><remote-ip>cluster24823.beta.local</remote-ip></syslog></ems-destination-create>').
2022-02-17 14:42:48,318 ERROR [oncommand] [...] Failed to Configure EMS for Cluster cluster15423
2022-02-17 14:44:25,413 ERROR [oncommand] [...] Failed to create EMS Destination cluster24823.beta.local on cluster20678. Error: Data ONTAP reported error code (13130), message: 'duplicate entry' (request: '<ems-destination-create><name>cluster24823.beta.local</name><syslog><remote-ip>cluster24823.beta.local</remote-ip></syslog></ems-destination-create>').