メインコンテンツまでスキップ

Sg6060アプライアンスがボリュームが優先パス上になく、ALBホストに互換性がないと報告する

Views:
4
Visibility:
Public
Votes:
0
Category:
storagegrid<a>2010073235</a>
Specialty:
sgrid
Last Updated:

環境

StorageGRID

  • Sg6060
 

問題

  • ALBに互換性がないホストドライバとVNOPP(ボリュームが優先パス上にありません) がSANtricityで報告される
  • StorageGRIDが、影響を受けたStorageGRIDアプライアンスに対するハードウェアアラートを報告する

Eシリーズのログから報告されるMELイベントの例を次に示します。
A:6/23/24, 1:27:54 AM (01:27:54) 22810 9103 Host multipath driver configuration error detected - Host StorageGRID Appliance <--CRITICAL
A:6/23/24, 1:26:52 AM (01:26:52) 22809 4011 Volume not on preferred path due to AVT/RDAC failover - Shelf 99, Bay A <--CRITICAL
A:6/23/24, 1:21:52 AM (01:21:52) 22808 2044 IO shipping implicit volume transfer - Volume StorageGRID-PGE-Backup
----> Shipped/Owned IOs: 62/0, Host ID: 6
A:6/23/24, 1:21:52 AM (01:21:52) 22807 212c Write-back caching fully restored - Shelf 99, Bay A
A:6/23/24, 1:21:52 AM (01:21:52) 22806 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay A - Event: Give Volume Ownership-2
B:6/23/24, 1:21:53 AM (01:21:53) 22805 212c Write-back caching fully restored - Shelf 99, Bay B
B:6/23/24, 1:21:52 AM (01:21:52) 22804 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay B - Event: Cache Reconfigure Sync-2
A:6/23/24, 12:26:06 AM (00:26:06) 22803 2049 Fail-back implicit volume transfer - Volume StorageGRID-PGE-Backup
A:6/23/24, 12:26:06 AM (00:26:06) 22802 212c Write-back caching fully restored - Shelf 99, Bay A
A:6/23/24, 12:26:06 AM (00:26:06) 22801 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay A - Event: Take Volume Ownership-2
B:6/23/24, 12:26:07 AM (00:26:07) 22800 212c Write-back caching fully restored - Shelf 99, Bay B
B:6/23/24, 12:26:06 AM (00:26:06) 22799 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay B - Event: Cache Reconfigure Sync-2
B:6/23/24, 12:21:36 AM (00:21:36) 22798 212c Write-back caching fully restored - Shelf 99, Bay B
B:6/23/24, 12:21:36 AM (00:21:36) 22797 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay B - Event: Cache Reconfigure Sync-2
A:6/23/24, 12:21:36 AM (00:21:36) 22796 2044 IO shipping implicit volume transfer - Volume StorageGRID-PGE-Backup
----> Shipped/Owned IOs: 43/13, Host ID: 6
A:6/23/24, 12:21:36 AM (00:21:36) 22795 212c Write-back caching fully restored - Shelf 99, Bay A
A:6/23/24, 12:21:35 AM (00:21:35) 22794 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay A - Event: Give Volume Ownership-2

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.