メタデータドライブのDriveMissingがコアを生成します。 VolReadWrite
- Views:
- 4
- Visibility:
- Public
- Votes:
- 0
- Category:
- element-software<a>2010015973</a>
- Specialty:
- solidfire
- Last Updated:
環境
- NetApp Elementソフトウェア 12.3.0.958
- NetApp H610S
問題
- NetApp SolidFire Active IQレポートの アラート:
- エラーコード:
sliceServiceUnhealthy
詳細:A metadata service is unhealthy and SolidFire is attempting to migrate data away from it.
- エラーコード:
driveFailed
詳細:1 drive(s) with state: "DriveMissing" driveID: xx.
- エラーコード:
- core.VolReadWrite-xx.xxxx.gz が生成されます
kern.log
エラーを報告します。
nvme nvme0: I/O 61 QID 29 timeout, aborting
nvme nvme0: I/O 567 QID 30 timeout, aborting
nvme nvme0: I/O 520 QID 31 timeout, aborting
nvme nvme0: I/O 942 QID 32 timeout, aborting
nvme nvme0: Abort status: 0x0
nvme nvme0: Abort status: 0x0
nvme nvme0: Abort status: 0x0
nvme nvme0: Abort status: 0x0
nvme nvme0: I/O 61 QID 29 timeout, reset controller
nvme nvme0: I/O 0 QID 0 timeout, reset controller
nvme nvme0: Device not ready; aborting reset
nvme nvme0: Device not ready; aborting reset
nvme nvme0: Removing after probe failure status: -19
nvme nvme0: Device not ready; aborting reset
print_req_error: 38 callbacks suppressed
print_req_error: I/O error, dev nvme0n1, sector 1464291080
print_req_error: I/O error, dev nvme0n1, sector 3122661848