環境

  • Brocade X7スイッチ
  • FOS v9.2.1a

問題

  • Brocade X7スイッチのスタンバイCPが再起動しました。
  • スタンバイCPは障害状態になり、デアサート状態に戻りました。

2025/04/28-02:03:56 (IST), [HAMK-1004], 2352808, SLOT 1 | CHASSIS, INFO, sw13, Resetting standby CP (double reset may occur).
2025/04/28-02:03:56 (IST), [FSSM-1003], 2352809, SLOT 1 | CHASSIS, WARNING, sw13, HA State out of sync.
2025/04/28-02:03:56 (IST), [EM-1033], 2352810, SLOT 1 | CHASSIS, ERROR, sw13, CP in Slot 2 set to faulty because CP ERROR asserted.
2025/04/28-02:03:59 (IST), [EM-1047], 2352811, SLOT 1 | CHASSIS, INFO, sw13, CP in slot 2 not faulty, CP ERROR deasserted.
2025/04/28-02:04:22 (IST), [MAPS-1021], 2352812, SLOT 1 | FID 128, WARNING, sw1, RuleName=defCHASSISHA_SYNC_0, Condition=CHASSIS(HA_SYNC/NONE==0), Obj:Chassis [HA_SYNC,0] has contributed to switch status MARGINAL.
2025/04/28-02:04:22 (IST), [MAPS-1020], 2352813, SLOT 1 | FID 128, WARNING, sw1, Switch wide status has changed from HEALTHY to MARGINAL.

  • スタンバイ パッケージのセカンダリ パーティションは Vpackage として表示されます。

firmwareshow -v:
Slot Name     Appl    Primary/Secondary Versions         Status
--------------------------------------------------------------------------
  1  CP0     FOS    v9.2.1a                  ACTIVE
             v9.2.1a                  
  2  CP1     FOS    v9.2.1a                  STANDBY *
             vpackage                 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.