メインコンテンツまでスキップ

BES-53248クラスタスイッチのSwitchIfIsDownWarm_Alertが報告されます

Views:
5
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2009471018</a>
Specialty:
HW
Last Updated:

環境

  • ONTAP 9
  • BES-53248クラスタスイッチ

問題

  • BES-53248クラスタスイッチのイベントログでは、次のアラートが報告されます。

[Node-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchIfIslDownWarn_Alert[CLUSW01/Slot: 0 Port: 55 100G - Level].

  • この問題 が原因でスイッチのヘルスがデグレードしています。

Cluster::> system health subsystem show
Subsystem      Health
----------------- ------------------
SAS-connect     ok
Environment     ok
Memory       ok
Service-Processor ok
Switch-Health    degraded
CIFS-NDO      ok
Motherboard     ok
IO         ok
MetroCluster    ok
MetroCluster_Node ok
FHM-Switch     ok
FHM-Bridge     ok
SAS-connect_Cluster
          ok
13 entries were displayed.

  • 両方のクラスタスイッチから報告されたISLポートのステータスが「停止」になっています。

CLUSW01# show port all

         Admin    Physical   Physical   Link   Link   LACP   Actor
Intf    Type   Mode    Mode     Status    Status Trap   Mode   Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/55   PC Mbr Enable   100G Full       Down  Enable  Enable long
0/56    PC Mbr Enable   100G Full  100G Full  Up    Enable  Enable long

  • ISLポートにケーブルが接続されていますが、次のエラーが発生しています:

CLUSW01# show fiber-ports optical-transceiver-info all

                 Link Link                      Nominal
                Length Length Link                  Bit Rate
    Number           50um 62.5um Length                 Per Lane
Port   of Lanes Vendor Name    [m] [m]    [m]   Serial Number   Part Number    [Mbps]   Rev  Compliance
------ -------- ---------------- --- ----   ------ ---------------- ---------------- -----   ---- ----------------
0/55   4    Molex       0   0    1M    93AXXXXXX0028   112-00573     25500    B0 100GBase-CR4

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.