メインコンテンツへスキップ

ネットワークの問題によるSwitchUnreachable_Alert

Views:
3
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • FAS/AFFシステム
  • クラスタスイッチ

問題

  • AutoSupportから: SwitchUnreachable_Alertがシステムで報告されました
[Node_01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchUnreachable_Alert , Alerting Resource = SW1(FOCXXXXXXXX) raised by monitor ethernet-switch
 
[Node_01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchUnreachable_Alert , Alerting Resource = SW2(FOCXXXXXXXX) raised by monitor ethernet-switch
  • 1つ以上のノードがクラスタスイッチとの通信に失敗しました
  • 以下のコマンドを実行すると、次も表示されます
    • Clsuter::> system health alert show Node: node1 Alert ID: SwitchUnreachable_Alert Resource: switch1(YYY26390XXX) Severity: Major Indication Time: Mon Mar 10 14:42:11 2025 Suppress: false Acknowledge: false Probable Cause: The ethernet switch's IP address is not reachable fromthe local node. Possible Effect: Monitoring of the switch and log collection will not function. Corrective Actions: Ensure that the IP address is reachable or specify the correct reachable IP address. Node: Node1 Alert ID: UnsupportedSwitch_Alert Resource: switch1(YYY26390XXX) Severity: Major Indication Time: Mon Mar 10 14:42:33 2025 Suppress: false Acknowledge: false Probable Cause: Unsupported Ethernet switch is detected. Possible Effect: Communication problems and network connectivity issues occur. Corrective Actions: Unsupported Ethernet switch "undcdsa-nsdb01(FDO26390U4P)" found. Connectsupported Ethernet switch to the network.
  • クラスタスイッチはCluster Switch Health Monitor(CSHM)によって監視されていません:
    • ClusterA::> system switch ethernet show
      Switch            Type         Address      Model
      --------------------------- ------------------ ---------------- ---------------
      switch_A_1(xxxxxxxxxxx)    cluster-network   10.1.1.X         NX3132V
         Serial Number: xxxxxxxxxxx
          Is Monitored: false 
            Reason: IP address not reachable
        Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 7.0(3)I4(1)
         Version Source: CDP

  • この結果、スイッチの健全性が低下します。

::> system health subsystem show
Subsystem         Health
----------------- ------------------      
SAS-connect       ok
Environment       ok
Memory            ok
Service-Processor ok
Switch-Health     degraded
CIFS-NDO          ok
Motherboard       ok

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.