CONTAP-492278: monitor.ioCard.degraded: IO カードが劣化しています
問題
システムは両方のノードで以下のアラートを報告しています [Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P4 Temp is not readable
[Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge Mach Temp is not readable
[Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P1 Temp is not readable
[Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P2 Temp is not readable
[Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P3 Temp is not readable
[Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P4 Temp is not readable
[Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge Mach Temp is not readable
[Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P1 Temp is not readable
SP-IPMIから IO8 Present PRESENT
IO8 Ready READY
IO8 INFO FRU_AVAIL
IO8 Status normal 57 -- -- -- --
IO8 64Ge Mach Temp failed -- C 0 C 5 C 100 C 105 C
IO8 64Ge P1 Temp failed -- C -5 C -1 C 70 C 75 C
IO8 64Ge P2 Temp failed -- C -5 C -1 C 70 C 75 C
IO8 64Ge P3 Temp failed -- C -5 C -1 C 70 C 75 C
IO8 64Ge P4 Temp failed -- C -5 C -1 C 70 C 75 C
IO8 64Ge Power Good GOOD
IO8 64Ge Volt Spikes normal 0 -- -- -- 3
サポートされているSFPを使用 slot 8: Fibre Channel Target Host Adapter 8a
(QLogic 2800 (2814) rev. 2, <ONLINE>)
Board Name: 111-05089
Serial Number: 042443000046
Firmware rev: 9.14.80
Host Port Addr: eb0060
FC Nodename: XXXXXXXXXXXXXXX (X)
FC Portname: XXXXXXXXXXXXXXX (X)
Connection: PTP, Fabric
Switch Port: DC-MDS9164V-TOP:1/45
SFP Vendor Name: WTD
SFP Vendor P/N: RTXM520-571 ==> https://hwu.netapp.com/Search/Index?keyword=RTXM520-571
SFP Vendor Rev: 1.0
SFP Serial No.: XXXXXXXXX
SFP Connector: LC
SFP Capabilities: 16, 32, 64 Gbit/Sec