環境

  • ONTAP 9
  • FAS/AFFシステム
  • SP(Service Processor)
  • BMC (Baseboard Management Controller)

問題

  • ネットワークインターフェイスを使用してSPファームウェアイメージを転送できないため、自動ファームウェアアップグレードが失敗しました。

Node03: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update has been successfully scheduled from  4.11 to 4.11P1'}[?]  
Node03: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update from 4.11 to 4.11P1 has been triggered.'}[?]  
Node03: servprocd: sp.servprocd.upd.unexpt.evts:debug]: params: {'reason': 'Unable to transfer SP firmware image using network interface'}
Node03: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.[?] 

または

Servprocd::SpUpdate: writeImage: spcs sp update command failed (SSL_CTX_use_PrivateKey_file: key values mismatch exception occurred in spcc_sp_update code)

  • system health statusshowdegradedです。

::*> system health status show
Status
---------------
degraded

  • system health alert show SPAutoUpgradeFailedMajorAlert.が表示されます

::*> system health alert show
        Node: Node1
      Alert ID: SPAutoUpgradeFailedMajorAlert
      Resource: SP Upgrade
      Severity: Major
   Indication Time: Sun 
      Suppress: false
     Acknowledge: false
   Probable Cause: A Service Processor automatic firmware update failure
           was detected, which can result in Service Processor
           not being updated to the latest available compatible
           firmware package.
   Possible Effect: Suboptimal system behavior can result from Service
           Processor not being updated to the latest available
           compatible firmware package.
Corrective Actions: 1. Use the "system service-processor image show" command to display the firmware version that SP is currently booted from.
           2. Manually upgrade Service Processor by using the "system service-processor image update" command.
           3. Allow sufficient time for the system to update Service Processor firmware to the specified SP firmware package.
           4. Contact the technical support if the alert persists.
        Node: Node2
      Alert ID: SPAutoUpgradeFailedMajorAlert
      Resource: SP Upgrade
      Severity: Major
   Indication Time: Sun 
      Suppress: false
     Acknowledge: false
   Probable Cause: A Service Processor automatic firmware update failure
           was detected, which can result in Service Processor
           not being updated to the latest available compatible
           firmware package.
   Possible Effect: Suboptimal system behavior can result from Service
           Processor not being updated to the latest available
           compatible firmware package.
Corrective Actions: 1. Use the "system service-processor image show" command to display the firmware version that SP is currently booted from.
           2. Manually upgrade Service Processor by using the "system service-processor image update" command.
           3. Allow sufficient time for the system to update Service Processor firmware to the specified SP firmware package.
           4. Contact the technical support if the alert persists.
2 entries were displayed.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 