ネットワーク インターフェイスの問題が原因でService Processorの自動ファームウェアが失敗しました
環境
- ONTAP 9
- FAS/AFFシステム
- SP(Service Processor)
- BMC (Baseboard Management Controller)
問題
- ネットワークインターフェイスを使用してSPファームウェアイメージを転送できないため、自動ファームウェアアップグレードが失敗しました。
Node03: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update has been successfully scheduled from 4.11 to 4.11P1'}[?]
Node03: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update from 4.11 to 4.11P1 has been triggered.'}[?]
Node03: servprocd: sp.servprocd.upd.unexpt.evts:debug]: params: {'reason': 'Unable to transfer SP firmware image using network interface'}
Node03: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.[?]
または
Servprocd::SpUpdate: writeImage: spcs sp update command failed (SSL_CTX_use_PrivateKey_file: key values mismatch exception occurred in spcc_sp_update code)
system health statusshowはdegradedです。
::*> system health status showStatus---------------degraded
system health alert showにSPAutoUpgradeFailedMajorAlert.が表示されます
::*> system health alert show Node: Node1 Alert ID: SPAutoUpgradeFailedMajorAlert Resource: SP Upgrade Severity: Major Indication Time: Sun Suppress: false Acknowledge: false Probable Cause: A Service Processor automatic firmware update failure was detected, which can result in Service Processor not being updated to the latest available compatible firmware package. Possible Effect: Suboptimal system behavior can result from Service Processor not being updated to the latest available compatible firmware package.Corrective Actions: 1. Use the "system service-processor image show" command to display the firmware version that SP is currently booted from. 2. Manually upgrade Service Processor by using the "system service-processor image update" command. 3. Allow sufficient time for the system to update Service Processor firmware to the specified SP firmware package. 4. Contact the technical support if the alert persists. Node: Node2 Alert ID: SPAutoUpgradeFailedMajorAlert Resource: SP Upgrade Severity: Major Indication Time: Sun Suppress: false Acknowledge: false Probable Cause: A Service Processor automatic firmware update failure was detected, which can result in Service Processor not being updated to the latest available compatible firmware package. Possible Effect: Suboptimal system behavior can result from Service Processor not being updated to the latest available compatible firmware package.Corrective Actions: 1. Use the "system service-processor image show" command to display the firmware version that SP is currently booted from. 2. Manually upgrade Service Processor by using the "system service-processor image update" command. 3. Allow sufficient time for the system to update Service Processor firmware to the specified SP firmware package. 4. Contact the technical support if the alert persists.2 entries were displayed.