シャーシファンFRUで障害が発生しました:複数のファンで障害が発生
環境
- FAS8200
- ONTAP 9
問題
- EMSからファンに関する複数のエラーが報告される
Mon Feb 20 09:42:57 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan1 F2
Mon Feb 20 09:42:57 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan2 F1
Mon Feb 20 09:44:02 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan2 F2
Mon Feb 20 09:44:27 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F1
Mon Feb 20 09:44:42 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F2
Mon Feb 20 10:42:40 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan1 F1
Mon Feb 20 10:42:59 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan1 F2
Mon Feb 20 10:43:00 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan2 F1
Mon Feb 20 10:44:06 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan2 F2
Mon Feb 20 10:44:30 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F1
Mon Feb 20 10:44:43 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F2
Mon Feb 20 09:00:00 +0900 [node1: statd: monitor.fan.failed:alert]: Multiple fans has failed: Sysfan1 F1, Sysfan1 F2, Sysfan2 F1, Sysfan2 F2, Sysfan3 F1, Sysfan3 F2.
Mon Feb 20 10:00:00 +0900 [node1: statd: monitor.fan.failed:alert]: Multiple fans has failed: Sysfan1 F1, Sysfan1 F2, Sysfan2 F1, Sysfan2 F2, Sysfan3 F1, Sysfan3 F2.
- SPセンサーのファンステータスが不良です
Sysfan3 F2 BAD
Sysfan3 F1 BAD
Sysfan2 F2 BAD
Sysfan2 F1 BAD
Sysfan1 F2 BAD
Sysfan1 F1 BAD
Chassis Thermal Zone OVER_TEMP
Thermal Shutdown UP
CPU0 Avg Critical NO
Temp Average Low NO
Temp Average High NO
CPU0 Temp Avg normal -65 C -- -- -11 C -1 C
InFlow Temp Avg normal 25 C 0 C 5 C 50 C 55 C
OutFlow Temp Avg normal 38 C 0 C 5 C 65 C 75 C
PCI Temp Avg normal 34 C 0 C 5 C 60 C 70 C
Bat Temp Avg normal 31 C 0 C 5 C 60 C 70 C
Amb2 Temp Avg invalid -- C 0 C 5 C 47 C 52 C
Amb1 Temp Avg invalid -- C 0 C 5 C 47 C 52 C
PSU2 FRU Fan OK
PSU2 FRU Power ON
PSU1 FRU Fan OK
PSU1 FRU Power ON
Fan3 INFO FAILED
Fan2 INFO FAILED
Fan1 INFO FAILED
PSU1 INFO FRU_AVAIL
PSU1 INFO FRU_AVAIL
Fan1 MULTIFAULT
Fan2 MULTIFAULT
Fan3 MULTIFAULT
PSU1 GOOD