メインコンテンツまでスキップ

40G / 100G CX5 NIC が Broadcom BES-53248 クラスタスイッチに接続されている場合の CRC エラー

Views:
38
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2008899241</a>
Specialty:
hw
Last Updated:

環境

  • FAS/AFF
  • BES-53248
  • クラスタ インターコネクト

問題

  • インバウンドパケットエラーに関するシステムアラート。

例:

cluster1::*> alert show
(system health alert show)
Node: cluster1-01
Resource: <switch port>
Severity: Major
Indication Time: Tue Feb 08 18:01:43 2022
Suppress: false
Acknowledge: false
Probable Cause: The percentage of inbound packet errors of switch
interface "switchname/<switch port>" is above the warning threshold.

  • CLUSTER NETWORK DEGRADED CRC Errors Detected BES-53248 に接続している場合は、すべてのクラスタポートのが原因です。
例:
<LR d="02Sep2021 13:17:24" n="node1" t="0000000" id="0/26207890441008" p="1" s="Ok" o="vifmgr" vf="" type="1" seq="180177" supp="98">
<callhome_clus_net_degraded_1
        subject="CLUSTER NETWORK DEGRADED"
        event_type="CRC Errors Detected"
        event_details="High CRC errors detected on port e0c node node1"/>
</LR>
  • クラスタ LIF からの ping でパケット損失が発生する。
例:
[?] Tue Sep 07 07:43:56 +0800 [node1: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif clusterlif (node node1) to cluster lif clusterlif(node node2)
  • イーサネットスイッチに対してクラスタアラートが生成 / 切断される回数が複数回発生しました。
例:
[?] Tue Sep 07 02:31:14 +0800 [na02: cshmd: hm.alert.raised:alert]: Alert Id = ClusterIfInErrorsWarn_Alert , Alerting Resource = CS1/Slot: 0 Port: 50 100G - Level raised by monitor ethernet-switch
[?] Tue Sep 07 02:31:14 +0800 [na02: cshmd: hm.alert.cleared:notice]: Alert Id = ClusterIfInErrorsWarn_Alert , Alerting Resource = CS2/Slot: 0 Port: 50 100G - Level cleared by monitor ethernet-switch
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 