P3.3V BATTはクリティカルローまたはハイです
環境
FAS / AFFシステム
問題
- EMSログで
P3.3V BATT is critical low/high
エラーが報告される。
[env_mgr: monitor.chassispower.degraded:ALERT]: Chassis power is degraded: Sensor detecting voltage anomalies.
[env_mgr: monitor.chassispower.degraded:ALERT]: Chassis power is degraded: P3.3V BATT is critical low (16 mV).
[env_mgr: monitor.chassispower.ok:NOTICE]: Chassis power is OK.
[env_mgr: monitor.chassispower.degraded:ALERT]: Chassis power is degraded: P3.3V BATT is critical high (4064 mV).
[env_mgr: monitor.chassispower.ok:NOTICE]: Chassis power is OK.
SP-LATEST-IPMI"
ログでは、RTCバッテリのステータスがnormalの値になっています。
===SP-LATEST-IPMI===
/usr/local/bin/ipmi sensors
===============================
Sensor Name |
Current | Unit | Status | LCR | LNC | UNC |
UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
P3V3_BATT | 0.160 | Volts | ok | 0.016 | 0.032 | 4.048 | 4.064
/usr/local/bin/environ -show_all
================================
Sensor Name State Current Critical Warning Warning
Critical Reading Low Low High
High
-------------------------------------------------------------------------------------------------
P3.3V BATT normal 160 mV 16 mV 32 mV 4048 mV 4064 mV