メインコンテンツへスキップ

SPがハングしたため、シャーシの電源装置がクリティカルステータスを示す

Views:
39
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

環境

  • AFF A700
  • FAS8200
  • chassisPower.degraded:アラート

問題

  • EMSは、Chassis Internal PSU can't be readとSPがhearbeatの喪失により同時にリブートすることを示しています。

[env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Temperature is Unreadable
[power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU1.
[spsm_listener: sp.heartbeat.stopped:error]: Have not received a IPMI heartbeat from the Service Processor (SP) in last 20 seconds.
[spsm_listener: callhome.sp.hbt.missed:notice]: Call home for SP HBT MISSED
[spsm_listener: sp.heartbeat.resumed:info]: Received IPMI heartbeat from the Service Processor (SP).

  • しばらくすると正常に戻る場合があります。

spmgmt.driver.timeout: The software driver for the Service Processor (SP) detected a problem: Unable to update SP network information at this time.
sp.heartbeat.resumed: Received IPMI heartbeat from the Service Processor (SP).
splog.running.normally: Process splogd is operating normally.
INFORMATIONAL monitor.chassisPowerSupplies.ok: Chassis power supplies OK.
NOTICE monitor.globalStatus.ok: The system's global status is normal.

 

  • SPのリブート後、SP-LATEST-IPMIPSUステータスは回復しましたが、複数のセンサーが異常なステータスを示しています。

Sensor Name | Current | Unit | Status | LCR | LNC | UNC | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
CPU0_Temp_Margin | na | degrees C | na | na | na | -5.000 | 0.000
In_Flow_Temp | -55.000 | degrees C | cr | 0.000 | 10.000 | 75.000 | 80.000
CPU_VCC | 0.010 | Volts | cr | 0.708 | 0.747 | 1.348 | 1.426
CPU_1.05V | 0.010 | Volts | cr | 0.892 | 0.941 | 1.154 | 1.203
CPU_VTT | 0.010 | Volts | cr | 0.931 | 0.989 | 1.213 | 1.261
LM56_Temp | na | degrees C | na | 0.000 | 10.000 | 72.000 | 77.000
CPU_1.5V | 0.010 | Volts | cr | 1.271 | 1.348 | 1.649 | 1.727
Bat_1.5V | 1.756 | Volts | cr | 1.280 | 1.348 | 1.649 | 1.727

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.