メインコンテンツまでスキップ

シャーシの電源装置に重大なステータスが表示され、SPが同時にリブートされる

Views:
23
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

環境

FAS8200

問題

  • EMS は、 ハートビート損失のためにシャーシ内部PSUを読み取ることができず、SPを再起動することを示しています。

[?] Wed Aug 02 06:47:16 +0900 [node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Temperature is Unreadable
[?] Wed Aug 02 06:47:25 +0900 [node-01: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU1.
[?] Wed Aug 02 06:48:35 +0900 [node-01: spsm_listener: sp.heartbeat.stopped:error]: Have not received a IPMI heartbeat from the Service Processor (SP) in last 20 seconds.
[?] Wed Aug 02 06:51:21 +0900 [node-01: spsm_listener: callhome.sp.hbt.missed:notice]: Call home for SP HBT MISSED
[?] Wed Aug 02 06:53:14 +0900 [node-01: spsm_listener: sp.update.status:debug]: params: {'reason': 'sp_startup_notify_servprocd: SP startup handler has been called. '}
[?] Wed Aug 02 06:53:14 +0900 [node-01: spsm_listener: sp.heartbeat.resumed:info]: Received IPMI heartbeat from the Service Processor (SP).

  • SPのリブート後、 SP-LATEST-IPMI PSUのステータスは回復したが、複数のセンサーのステータスが異常であることが示される。

Sensor Name | Current | Unit | Status | LCR | LNC | UNC | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
CPU0_Temp_Margin | na | degrees C | na | na | na | -5.000 | 0.000
In_Flow_Temp | -55.000 | degrees C | cr | 0.000 | 10.000 | 75.000 | 80.000
CPU_VCC | 0.010 | Volts | cr | 0.708 | 0.747 | 1.348 | 1.426
CPU_1.05V | 0.010 | Volts | cr | 0.892 | 0.941 | 1.154 | 1.203
CPU_VTT | 0.010 | Volts | cr | 0.931 | 0.989 | 1.213 | 1.261
LM56_Temp | na | degrees C | na | 0.000 | 10.000 | 72.000 | 77.000
CPU_1.5V | 0.010 | Volts | cr | 1.271 | 1.348 | 1.649 | 1.727
Bat_1.5V | 1.756 | Volts | cr | 1.280 | 1.348 | 1.649 | 1.727

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.