DS460ディスク シェルフ障害
環境
DS460Cディスク シェルフ
 問題
チャネル 0b に接続されている DS460C ディスク ストレージ シェルフ 21 で重大な障害が報告されました
 EMS
Mon Aug 11 03:35:54 [node-1: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.Mon Aug 11 03:36:00 [node-1: monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.Mon Aug 11 03:36:03 [node-1: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N xxxxxxxxxxxxxxx) shelf 21 on channel 0b temperature warning for Temperature sensor 15: not installed or failed. Current temperature: 37 C (98 F). This module is on the front of the shelf 3rd drawer from the top, module A sensor 2.Mon Aug 11 03:36:03 [node-1: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N xxxxxxxxxxxxxxx) shelf 21 on channel 0b temperature warning for Temperature sensor 25: not installed or failed. Current temperature: 36 C (96 F). This module is on the front of the shelf 3rd drawer from the top, module B sensor 2.ストレージ障害
Enclosure Status: normalChannel: 0bShelf: 21Shelf Type: DS460-12Product Serial Number: xxxxxxxxxxxxxxxModule Type: IOM12BDisk Elements:Element Status          Status Bytes  Status Descriptions0 [Bay  0]: NOT AVAILABLE   07,00,00,001 [Bay  1]: NOT AVAILABLE   07,01,00,002 [Bay  2]: NOT AVAILABLE   07,02,00,003 [Bay  3]: NOT AVAILABLE   07,03,00,004 [Bay  4]: NOT AVAILABLE   07,04,00,005 [Bay  5]: NOT AVAILABLE   07,05,00,006 [Bay  6]: NOT AVAILABLE   07,06,00,007 [Bay  7]: NOT AVAILABLE   07,07,00,008 [Bay  8]: NOT AVAILABLE   07,08,00,009 [Bay  9]: NOT AVAILABLE   07,09,00,0010 [Bay 10]: NOT AVAILABLE   07,0A,00,0011 [Bay 11]: NOT AVAILABLE   07,0B,00,0012 [Bay  0]: OK         01,00,00,0013 [Bay  1]: OK         01,01,00,0014 [Bay  2]: OK         01,02,00,0015 [Bay  3]: OK         01,03,00,0016 [Bay  4]: OK         01,04,00,0017 [Bay  5]: OK         01,05,00,0018 [Bay  6]: OK         01,06,00,0019 [Bay  7]: OK         01,07,00,0020 [Bay  8]: OK         01,08,00,0021 [Bay  9]: OK         01,09,00,0022 [Bay 10]: OK         01,0A,00,0023 [Bay 11]: OK         01,0B,00,0024 [Bay  0]: OK         01,00,00,0025 [Bay  1]: OK         01,01,00,0026 [Bay  2]: OK         01,02,00,0027 [Bay  3]: OK         01,03,00,0028 [Bay  4]: OK         01,04,00,0029 [Bay  5]: OK         01,05,00,0030 [Bay  6]: OK         01,06,00,0031 [Bay  7]: OK         01,07,00,0032 [Bay  8]: OK         01,08,00,0033 [Bay  9]: OK         01,09,00,0034 [Bay 10]: OK         01,0A,00,0035 [Bay 11]: OK         01,0B,00,0036 [Bay  0]: OK         01,00,00,0037 [Bay  1]: OK         01,01,00,0038 [Bay  2]: OK         01,02,00,0039 [Bay  3]: OK         01,03,00,0040 [Bay  4]: OK         01,04,00,0041 [Bay  5]: OK         01,05,00,0042 [Bay  6]: OK         01,06,00,0043 [Bay  7]: OK         01,07,00,0044 [Bay  8]: OK         01,08,00,0045 [Bay  9]: OK         01,09,00,0046 [Bay 10]: OK         01,0A,00,0047 [Bay 11]: OK         01,0B,00,0048 [Bay  0]: OK         01,00,00,0049 [Bay  1]: OK         01,01,00,0050 [Bay  2]: OK         01,02,00,0051 [Bay  3]: OK         01,03,00,0052 [Bay  4]: OK         01,04,00,0053 [Bay  5]: OK         01,05,00,0054 [Bay  6]: OK         01,06,00,0055 [Bay  7]: OK         01,07,00,0056 [Bay  8]: OK         01,08,00,0057 [Bay  9]: OK         01,09,00,0058 [Bay 10]: OK         01,0A,00,0059 [Bay 11]: OK         01,0B,00,00Drawers Control Module:Element Status            Status Bytes  Status Descriptions1 [IOM12B A]   : CRITICAL      02,40,00,00  FAIL2 [IOM12B A]   : OK         01,00,01,01  REPORT, TYPE BIT03 [IOM12B A]   : OK         01,00,01,01  REPORT, TYPE BIT04 [IOM12B A]   : OK         01,00,01,01  REPORT, TYPE BIT05 [IOM12B A]   : OK         01,00,01,01  REPORT, TYPE BIT06 [IOM12B B]   : CRITICAL      02,40,00,00  FAIL7 [IOM12B B]   : OK         01,00,01,01  REPORT, TYPE BIT08 [IOM12B B]   : OK         01,00,01,01  REPORT, TYPE BIT09 [IOM12B B]   : OK         01,00,01,01  REPORT, TYPE BIT010 [IOM12B B]   : OK         01,00,01,01  REPORT, TYPE BIT0環境
 Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29; with error: noneShelf temperatures by element:[1] 20 C (68 F) (ambient)  Normal temperature range[2] 29 C (84 F)  Normal temperature range[3] 30 C (86 F)  Normal temperature range[4] 30 C (86 F)  Normal temperature range[5] 29 C (84 F)  Normal temperature range[6] 31 C (87 F)  Normal temperature range[7] 31 C (87 F)  Normal temperature range[8] 32 C (89 F)  Normal temperature range[9] 34 C (93 F)  Normal temperature range[10] Unavailable[11] 32 C (89 F)  Normal temperature range[12] 31 C (87 F)  Normal temperature range[13] 33 C (91 F)  Normal temperature range[14] 32 C (89 F)  Normal temperature range[15] Unavailable[16] 33 C (91 F)  Normal temperature range[17] 32 C (89 F)  Normal temperature range[18] 32 C (89 F)  Normal temperature range[19] 33 C (91 F)  Normal temperature range[20] Unavailable[21] 30 C (86 F)  Normal temperature range[22] 31 C (87 F)  Normal temperature range[23] 32 C (89 F)  Normal temperature range[24] 31 C (87 F)  Normal temperature range[25] Unavailable[26] 32 C (89 F)  Normal temperature range[27] 31 C (87 F)  Normal temperature range[28] 30 C (86 F)  Normal temperature range[29] 32 C (89 F)  Normal temperature rangeDCM installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10; with error: 1, 6DCM information by element:[1] Serial number:  Part number:Type:  Vendor:  Firmware version:[2] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805[3] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805[4] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805[5] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805[6] Serial number:  Part number:Type:  Vendor:  Firmware version:[7] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805[8] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805[9] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805[10] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805