FAS2620/FAS2650が(Battery PCT capacity critical)エラーにより停止
環境
- ONTAP 9
- SP FW 5.10以降
- FAS2620 / FAS2650
問題
(BATTERY (full charge capacity low)) EMERGENCY
ASUP がトリガーされます。
HA Group Notification (BATTERY (full charge capacity low)) EMERGENCY
- NVMEM バッテリ エラーが原因でノードが停止しています。
[env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery PCT capacity critical)
- ノードのシャットダウン中にバッテリ学習サイクルは発生しません。
[IPMI.emergency]: triggered OS halt: Battery PCT capacity critic
[IPMI.notice]: d501 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
[ONTAP.notice]: Appliance user command halt.
[IPMI.notice]: d601 | 02 | EVT: 6f03ffff | Sensor 255 | Assertion Event, "Storage OS graceful shutdown"
[IPMI Event.critical]: System power down
[IPMI.emergency]: Shutdown by Data ONTAP
[Trap Event.critical]: hwassist abnormal_reboot (28)
[IPMI.notice]: d701 | 02 | EVT: 0300ffff | Power_Good | Assertion Event, "State Deasserted"
[ASUP.notice]: First notification email | (REBOOT (abnormal)) WARNING | Sent
Bat Pct Capacity
クリティカル ローとしてマークされています。
バッテリー容量 critlow 32 % 39 % 44 % -- --