メインコンテンツへスキップ

HOST_PORT_FAIL - 不良 SAS ケーブルによる IOM アラートにより無効化

Views:
144
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • AFFシステム
  • FASシステム
  • ディスク シェルフ

問題

  • 以下のイベントがEMSログに記録されます:

[node-02: dsa_worker0: ds.sas.running.disparity:debug]: [HST2/P0:2] on channels 0b shelf ID 1 IOM B bay - reports running disparity errors.
[node-02: dsa_worker2: ds.sas.hostphy.disableErr:alert]: Port [HST2/P0:3] on channels 0b shelf ID 1 IOM B disabled due to excessive invalid dword error.
[node-02: dsa_worker2: callhome.hostport.disable:alert]: Call home for HOST_PORT_FAIL - Disabled by IOM
[mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm:DegradedOnlineShelfPort_Alert[*****:3].
[start_asup_collector_thread: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.
[start_asup_collector_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

  • STORAGE-SHELFセクションから、影響を受けるPHYが過度のエラーのためにディスエーブルになっていることがわかります: 

Shelf name:   0a.shelf1
Shelf id:    1
Channel:     0a
Module:     B
Shelf UID:    50:0a:09:80:07:fa:d6:80
Shelf S/N:    SHJSXXXXXXXXXXX
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK

                     Partial Path   Link    Invalid   Running     Loss    Phy       CRC     Phy
Disk          Port   Timeout        Rate     DWord    Disparity   Dword   Reset     Error   Change
Id           State   Value (ms)    (Gb/s)    Count    Count       Count   Problem   Count   Count
--------------------------------------------------------------------------------------------------
[HST0/P0:0 ] OK             7       12.0        0           0       0        0         0       3
[HST1/P0:1 ] OK             7       12.0        0           0       0        0         0       3
[HST2/P0:2 ] DIS/INVWD     7         NA     3496     2806      0        0         0       4
[HST3/P0:3 ] DIS/INVWD   7      NA   6598     3415     0     0      0    20

  • 該当するSASポートで、PHYが不明または無効と報告されます:

slot 0: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <UP>)
       Firmware rev:     03.08.09.00
       Base WWN:       5:00a098:003cf2e:30
       Temperature:     Not Available
       Phy State:      [0] Enabled, 12.0 Gb/s
                 [1] Enabled, 12.0 Gb/s
                 [2] Enabled, Rate unknown
                 [3] Disabled

  • SAS-EXPANDER-PHY-STATE 影響を受けたSASポートが不明と報告される:

                Pwr      Invald Disprt Loss   Phy   CRC   Phy           
              Pwr Ccl Rsv Rls DWord  Error  Sync   Reset  Error  Change SATA       
PHY/BAY STATE        ON  Cnt Cnt Cnt Count  Count  Count  Prob   Cnt   Cnt   Affiliation    
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------    
 8/P2:0 Rate unknown    
 9/P2:1 12.0 Gb/s      --- --- --- --- 0    0    0    0    0    1    ----------------
10/P2:2 12.0 Gb/s      --- --- --- --- 0    0    0    0    0    1    ----------------
11/P2:3 12.0 Gb/s      --- --- --- --- 0    0    0    0    0    1    ----------------

  • SYSTEM-HEALTH-ALERT.XML レポートDegradedOnlineShelfPort_Alert

Alert ID:DegradedOnlineShelfPort_Alert
Description:Shelf-to-shelf connection between disk shelves x.x x port and x.x x port have 1 inactive PHYs on IOM B.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • この記事は役に立ちましたか?