メインコンテンツまでスキップ

メンテナンスまたは交換後のシェルフセンサーしきい値が正しくありません

環境

  • FASシステム 
  • AFFシステム

問題

ハードウェアのメンテナンスや交換後、環境ログにシェルフセンサーのしきい値が正しくありません。これは一方のノードでのみ誤って報告され、パートナーからは正しく報告されません。
 
例:
Temperature thresholds by element: [1] High critical: 52 C (125 F); high warning: 47 C (116 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [2] High critical: 60 C (140 F); high warning: 55 C (131 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [3] High critical: 60 C (140 F); high warning: 55 C (131 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [4] High critical: 60 C (140 F); high warning: 55 C (131 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [5] High critical: 60 C (140 F); high warning: 55 C (131 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [6] High critical: 62 C (143 F); high warning: 57 C (134 F) Low critical: 5 C (41 F); low warning: 10 C (50 F) [7] High critical: 100 C (212 F); high warning: 95 C (203 F) Low critical: 5 C (41 F); low warning: 10 C (50 F) [8] High critical: 62 C (143 F); high warning: 57 C (134 F) Low critical: 5 C (41 F); low warning: 10 C (50 F) [9] High critical: 100 C (212 F); high warning: 95 C (203 F) Low critical: 5 C (41 F); low warning: 10 C (50 F) [10] High critical: 90 C (194 F); high warning: 80 C (176 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [11] High critical: 100 C (212 F); high warning: 79 C (174 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [12] High critical: 75 C (167 F); high warning: 60 C (140 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [13] High critical: 65516 C (117960 F); high warning: 65516 C (117960 F) Low critical: 65516 C (117960 F); low warning: 65516 C (117960 F) [14] High critical: 65516 C (117960 F); high warning: 65516 C (117960 F) Low critical: 65516 C (117960 F); low warning: 65516 C (117960 F) [15] High critical: 65516 C (117960 F); high warning: 65516 C (117960 F) Low critical: 65516 C (117960 F); low warning: 65516 C (117960 F)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.