BMCのアップグレード後に複数のセンサーが「読み取り不能」になる
環境
- AFF-A400
- ONTAP 9.7P17
- BMC 13.11P1
問題
- BMCのアップグレード後、「
No Reading
」を報告するノードの複数のセンサーが検出されます。
bmc log debug
ログ、
======================================
Self Test: (run for 1 sec)
Selftest: passed
Sensor Reading: (run for 1 sec)
PilotIV | 00h | ok | 0.1 | Dynamic MC @ 20h
PVCCIN_CPU0 | 01h | ns | 21.1 | No Reading
PVCCIN_CPU1 | 02h | ns | 21.1 | No Reading
PVDDQ_ABC | 03h | ns | 21.1 | No Reading
PVDDQ_DEF | 04h | ns | 21.1 | No Reading
PVDDQ_GHI | 05h | ns | 21.1 | No Reading
PVDDQ_KLM | 06h | ns | 21.1 | No Reading
P1V05_PCH | 07h | ns | 21.1 | No Reading
System_Inlet | 10h | ok | 7.1 | 23 degrees C
CX5_Inlet | 11h | ns | 7.2 | No Reading
System_Outlet | 12h | ok | 7.3 | 30 degrees C
NVMe_Temp | 13h | ok | 7.4 | 24 degrees C
CX5_Temp1 | 14h | ns | 7.5 | No Reading
CX5_Temp2 | 15h | ns | 7.6 | No Reading
LED1_Temp | 16h | ok | 12.1 | 22 degrees C
LED2_Temp | 17h | ok | 12.1 | 22 degrees C
MP_Temp1 | 18h | ok | 15.1 | 23 degrees C
MP_Temp3 | 19h | ok | 15.1 | 23 degrees C
RiserL_Temp1 | 1Ah | ns | 11.1 | No Reading
RiserL_Temp2 | 1Bh | ns | 11.1 | No Reading
RiserM_Temp1 | 1Ch | ns | 11.2 | No Reading
RiserM_Temp2 | 1Dh | ns | 11.2 | No Reading
RiserM_Temp3 | 1Eh | ns | 11.2 | No Reading
RiserM_Temp4 | 1Fh | ns | 11.2 | No Reading
RiserR_Temp1 | 20h | ns | 11.3 | No Reading
RiserR_Temp2 | 21h | ns | 11.3 | No Reading
RiserR_Temp3 | 22h | ns | 11.3 | No Reading
RiserR_Temp4 | 23h | ns | 11.3 | No Reading
CPU0_Temp | 24h | ns | 3.1 | No Reading
CPU1_Temp | 25h | ns | 3.2 | No Reading
Mezz_Temp1 | 3Ch | ns | 11.4 | No Reading
Mezz_Temp2 | 3Dh | ns | 11.4 | No Reading
Bat_Temp | 40h | ok | 40.1 | 23 degrees C
- PSU関連のアラートも報告されますが、自動的にリカバリできます。
[monitor.chassisPower.degraded:alert]: Chassis power is degraded: PVCCIN CPU0 is critical low (1 mV).
[env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 PIN is Unreadable
[env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 POUT is Unreadable
[ env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 PIN is Unreadable
[env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 POUT is Unreadable
[ power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU2, PSU1.
[power_low_monitor: callhome.chassis.power:error]: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2, PSU1.
[monitor.chassisPower.ok:notice]: Chassis power is OK.
[monitor.globalStatus.critical:EMERGENCY]: Power Supply Status Critical: PSU2, PSU1.
[env_mgr: monitor.chassisPowerSupply.ok:info]: Chassis power supply 1 is OK.
[env_mgr: monitor.chassisPowerSupply.ok:info]: Chassis power supply 2 is OK.
[ power_low_monitor: monitor.chassisPowerSupplies.ok:info]: Chassis power supplies OK.
[env_mgr: callhome.chassis.ps.ok:notice]: Call home for CHASSIS POWER SUPPLY OK: PS 1
[env_mgr: callhome.chassis.ps.ok:notice]: Call home for CHASSIS POWER SUPPLY OK: PS 2