NSM100モジュールシェルフfwの0306へのアップグレードが失敗しました
環境
- ONTAP 9
- NSM100
- NS224シェルフ
問題
- SYSCONFIG -Aは、シェルフfwを0231から0306にアップグレードした後、1つのNSM100モジュールに変化がないことを示しています
Shelf 1: NS224NSM100 Firmware rev. NSM100 A: 0306 NSM100 B: 0231
- Node report
NoPathFromSwitchToNSM_Alert同時に。 EMSシェルフfwのアップグレード後にNSM100モジュールを再起動すると、NSM100モジュールセンサーが読み取り不能になると報告されます。
[node01: dsa_sfu: sfu.downloadingController:info]: [storage download shelf]: Downloading NSM100.0306.SFW on disk shelf controller module B on 0x.shelf1.
[node01: dsa_sfu: sfu.rebootRequest:info]: Issuing a request to reboot disk shelf 0x.shelf1 module B.
[node01: dsa_worker5: ses.status.electronicsWarn:error]: NS224NSM100 (S/N xxxxxxx) shelf 1 on channel 0x environmental monitoring warning for SES electronics 2: communication error. ; enclosure services hardware failed This element is on the rear of the shelf at the bottom, on module B.
[node01: dsa_worker5: ses.status.ModuleWarn:alert]: NS224NSM100 (S/N xxxxxxx) shelf 1 on channel 0x PCI switch warning for PCI Switch 2: communication error. This element is on the rear of the shelf at the bottom, on module B.
[node01: dsa_worker5: ses.status.ACPWarn:error]: NS224NSM100 (S/N xxxxxxx) shelf 1 on channel 0x ACP Processor warning for shelf ACP processor 2: communication error. ; Alternate Control Path hardware failed e B.
[node01: dsa_worker5: ses.status.dimm.error:error]: NS224NSM100 (S/N xxxxxxx) shelf 1 on channel 0x DIMM failure for Dimm Element 5: not installed or failed. This element is on the DIMM slot 1 in the bottom shelf module (B).
[node01: dsa_worker5: ses.status.dimm.error:error]: NS224NSM100 (S/N xxxxxxx) shelf 1 on channel 0x DIMM failure for Dimm Element 6: not installed or failed. This element is on the DIMM slot 2 in the bottom shelf module (B).
[node01: dsa_worker5: ses.status.dimm.error:error]: NS224NSM100 (S/N xxxxxxx) shelf 1 on channel 0x DIMM failure for Dimm Element 7: not installed or failed. This element is on the DIMM slot 3 in the bottom shelf module (B).
[node01: dsa_worker5: ses.status.dimm.error:error]: NS224NSM100 (S/N xxxxxxx) shelf 1 on channel 0x DIMM failure for Dimm Element 8: not installed or failed. This element is on the DIMM slot 4 in the bottom shelf module (B).
[node01: dsa_worker5: ses.status.battery.error:error]: NS224NSM100 (S/N xxxxxxx) shelf 1 on channel 0x battery failure error for Coin Battery 2: not installed or hardware failure. This element is on the rear of the shelf, in bottom module (B).
[node01: dsa_worker5: ses.status.etherConn.warn:error]: NS224NSM100 (S/N xxxxxxx) shelf 1 on channel 0x Ethernet connector warning for port e0a: cannot communicate with connector. This element is on the rear of the shelf at the bottom, on module B.
[node01: dsa_worker5: ses.status.etherConn.warn:error]: NS224NSM100 (S/N xxxxxxx) shelf 1 on channel 0x Ethernet connector warning for port e0b: cannot communicate with connector. This element is on the rear of the shelf at the bottom, on module B.
[node01: dsa_disc: ses.mismatch.fw.version:error]: The disk shelf modules on disk shelf 0x.1 are running two different firmware versions. Disk shelf module A is running 0306, and disk shelf module B is running 0231.
- 手動シェルフfw アップグレード
cluster::>storage shelf firmwareupdateでは問題は解決しません。 - NSM100 モジュールの再装着では問題は解決しません。