「Waiting for SP ...」でノードがブートできず、すべてのセンサーは良好です
環境
- FAS2720
- ONTAP 9
問題
- 計画的シャットダウン後、ノードをブートできず、次のメッセージが表示されます:
Record 1860: Sun May 26 01:59:45.750000 2024 [BMC.critical]: Filer Reboots
Record 1862: Sun May 26 01:59:49.300000 2024 [IPMI.notice]: 0089 | 02 | EVT: 6fc200ff | System_FW_Status | Assertion Event, "System software has cleanly shut down"
Record 1863: Sun May 26 01:59:50.000000 2024 [BMC.emergency]: System input power lost
Record 1864: Sun Jan 01 00:00:22.430000 2017 [IPMI.notice]: 008a | c0 | OEM: ffff7000ff00 | ManufId: 150300 | BMC Power Reset
Record 1865: Sun Jan 01 00:00:22.440000 2017 [IPMI.notice]: 008b | c0 | OEM: fcff70560000 | ManufId: 150300 | POS Register: Power on Reset(Normal Power Cycle)
Record 1866: Sun May 26 04:07:04.000000 2024 [SysFW.notice]: SP responded to sync command in 0 seconds.
Record 1867: Sun May 26 04:07:04.000000 2024 [SysFW.notice]: BIOS Version: 11.7
Record 1868: Sun May 26 04:07:06.000000 2024 [SysFW.notice]: Waiting for SP ...
Record 1869: Sun May 26 04:07:06.000000 2024 [SysFW.notice]: IPMI:Read midplane FRU common header:device busy. Retrying
Record 1870: Sun Jan 01 00:00:37.890000 2017 [BMC.notice]: Running primary version 11.8Record 1903: Sun May 26 04:12:29.490000 2024 [BMC.notice]: Switch is running on latest version 19
Record 1904: Sun May 26 04:19:20.800000 2024 [BMC.critical]: Heartbeat stopped
- SPログではすべてのセンサーが正常と表示されます。