環境

  • NetApp AFF-C30
  • ONTAP 9

問題

  • BMC イベントレポート PSU エラー:

Record 378: Thu May 28 00:09:14.386513 2026 [IPMI.notice]: 0106 | 02 | EVT: 6f02ffff | PSU2_Status | Assertion Event, "Attention"
Record 379: Thu May 28 00:09:14.440190 2026 [IPMI.notice]: 0107 | 02 | EVT: ef03ffff | PSU2_Status | Deassertion Event, "OUTPUT OK"
Record 380: Thu May 28 00:09:26.161900 2026 [IPMI.notice]: 0108 | 02 | EVT: 6f02ffff | PCM_Status | Assertion Event, "Fault"
Record 381: Thu May 28 00:09:50.672406 2026 [BMC.warning]: PSU2 status word assert: 0x0841
Record 382: Thu May 28 00:09:59.581387 2026 [IPMI.notice]: 0109 | 02 | EVT: 0301ffff | PSU2_Fault_Sum | Assertion Event, "State Asserted"
Record 383: Thu May 28 00:10:03.018882 2026 [IPMI.notice]: 010a | 02 | EVT: 015000ba | PSU2_12V_VOUT | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 11.160
Record 384: Thu May 28 00:10:03.371120 2026 [IPMI.notice]: 010b | 02 | EVT: 01500000 | PSU2_12V_IOUT | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 0.000
Record 385: Thu May 28 00:10:11.702553 2026 [IPMI.notice]: 010c | 02 | EVT: 015200b0 | PSU2_12V_VOUT | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 10.560
Record 386: Thu May 28 00:10:11.900306 2026 [IPMI.notice]: 010d | 02 | EVT: 01520000 | PSU2_12V_IOUT | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 0.000
Record 387: Thu May 28 00:10:29.679407 2026 [IPMI.notice]: 010e | 02 | EVT: 01500000 | PSU2_IIN | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 0.000
Record 388: Thu May 28 00:10:38.712746 2026 [IPMI.notice]: 010f | 02 | EVT: 01520000 | PSU2_IIN | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 0.000

  • ONTAP が CriticalFruMultiFaultAlert を報告します
  • ONTAP が CHASSIS POWER SUPPLY NEED TO BE REPLACED: PS 2 に対して AutoSupport をトリガーします
  • BMC の再起動では問題が解決しません。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.