メインコンテンツまでスキップ

SASエクスパンダがシャーシLEDをオンにしました

Views:
16
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009424153</a>
Last Updated:

環境

  • AFF A200
  • FAS 2750

問題

  • 両方のノードでシステム障害LEDがオレンジに点灯。

例:

200::*> system controller service-event show
               
Node        ID  Event Location            Event Description
---------------- --- ----------------------------------  ----------------------
A200-01      1   Chassis 1               SAS Expander has set the Chassis LED ON
A200-02      1   Chassis 1               SAS Expander has set the Chassis LED ON

  • モジュールA/Bエキスパンダの温度がFAILEDと表示されます。

例:

A200::*> system node environment sensors show

Node Sensor          State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
A200-01
   CPU0 Temp Margin    
            init-failed
                     - C      -     -     0    -1
   CPU0 Core Temp     normal
                    38 C      0     5    90    100
   PCM_Inlet_Temp     normal
                    28 C      0     5    67    72
A200-02
   PSU2 FRU        normal
                     GOOD
   PSU1 FRU        normal
                     GOOD
   SP Status        normal
                  IPMI_HB_OK
   Partner Status     
           not-available
   PSU1 Present      
           not-available
   PSU1 5V         
           not-available
                     - mV      -     -     -     -
   PSU1 12V        
           not-available
                     - mV      -     -     -     -
   PSU1 5V Curr      
           not-available
                     - mA      -     -     -     -
   PSU1 12V Curr      
           not-available
                     - mA      -     -     -     -
   PSU1 Fan 1       
           not-available
                     - RPM     -     -     -     -
   PSU1 Fan 2       
           not-available
                     - RPM     -     -     -     -
   PSU1 Inlet Temp     
           not-available
                     - C      0     5    57    62
   PSU1 Hotspot Temp    
           not-available
                     - C      0     5    90    100
   PSU2 Present      
           not-available
   PSU2 5V         
           not-available
                     - mV      -     -     -     -
   PSU2 12V        
           not-available
                     - mV      -     -     -     -
   PSU2 5V Curr      
           not-available
                     - mA      -     -     -     -
   PSU2 12V Curr      
           not-available
                     - mA      -     -     -     -
   PSU2 Fan 1       
           not-available
                     - RPM     -     -     -     -
   PSU2 Fan 2       
           not-available
                     - RPM     -     -     -     -
   PSU2 Inlet Temp     
           not-available
                     - C      0     5    57    62
   PSU2 Hotspot Temp    
           not-available
                     - C      0     5    90    100
   PSU_FAN         
           not-available
   Module B Expander Temp 
              failed
                     - C      0     5    80    90
   Module A Expander Temp 
              failed
                     - C      0     5    80    90
   Midplane 4 Temp     failed
                     - C      0     5    55    60
   Midplane 3 Temp     failed
                     - C      0     5    55    60
   Midplane 2 Temp     failed
                     - C      0     5    55    60
   Midplane 1 Temp     failed
                     - C      0     5    55    60
   Ambient Temp      failed
                     - C      0     5    47    52

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.