メインコンテンツまでスキップ

バグ1319203の修正バージョンのNS224のセンサー7またはセンサー13の過熱警告

Views:
14
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009917184</a>
Last Updated:

環境

  • NS224
  • ファームウェア02.31を実行しているNSM100モジュール

問題

  • センサー7または13の過熱(NSMモジュールAまたはBのCPUセンサー)
[node_name: dsa_worker4: ses.status.temperatureWarning:alert]: NS224NSM100 (S/N 123456789) shelf 0 on channel 0x temperature warning for Temperature sensor 7: non-critical status; overtemperature warning. Current temperature: 88 C
(190 F). This element is on the unknown location
 
[node_name: dsa_worker4: ses.status.temperatureWarning:alert]: NS224NSM100 (S/N 123456789) shelf 0 on channel 0x temperature warning for Temperature sensor 13: non-critical status; overtemperature warning. Current temperature: 88 C
(190 F). This element is on the unknown location
  • 1時間ごとのEMSエラー:
[node_name: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0x. Check fans, power supplies, disks, and temperature sensors.
  • storage show fault AutoSupportの出力例:

Enclosure Status: non-critical
Channel: 0x
Shelf: 0
Shelf Type: NS224NSM100
Module Type: NSM100
Temperature Sensors:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,2A,00
  ...
 12: OK         01,00,2E,00
 13: NONCRITICAL     03,00,6C,04   OT WARNING
 14: OK         01,00,3C,00
 ...
 17: OK         01,00,3D,00
Enclosure:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,02,00   FAIL

  • Environment AutoSupportの出力 例:

Channel: 0x
   Shelf: 10
   SES device path: local access: 0x.10.1.99
   Module type: NSM100; monitoring is active
   Shelf status: non-critical  condition
   SES Configuration, shelf 10:
    ...     
    Temperature Sensor installed element list: 1, 2, 3, ...15, 16, 17; with error: 13
   Shelf temperatures by element:
    [1] 19 C (66 F) (ambient)  Normal temperature range
    ...
    [12] 22 C (71 F)  Normal temperature range
    [13] 88 C (190 F) Overtemperature warning!

  • ::> storage shelf show 出力例:

Temperature:
         -- Thresholds °C --
   Temp Is     Low  Low High High Operational
 ID  Â°C Ambient Crit Warn Crit Warn Status        Sensor Location
--- ---- ------- ---- ---- ---- ---- ------------------ --------------------------------
  1   19 true     0   5   52   47 normal        ambient temp sensor on ODP board
  2   24 false    0   5   60   55 normal        temp sensor on midplane left
 ...  
  7   35 false    0   5   90   85 normal        CPU package on top module
 ...
 12   22 false    0   5   65   60 normal        bottom module temp sensor near midplane
 13   88 false    0   5   90   85 over-temperature   CPU package on bottom module
 14   45 false    0   5   85   80 normal        Ethernet port 1 on bottom module
 ...

  • storage fault 出力例:
::> system node run -nodde node_name -command storage show fault
Temperature Sensors:
Element Status         Status Bytes  Status Descriptions
1: OK                01,00,27,00
...
6: OK                01,00,33,00                 
7: NONCRITICAL       03,00,6C,04   OT WARNING
8: OK                01,00,4C,00
...
             17: OK                01,00,44,00

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 