メインコンテンツまでスキップ

BMC CLIでは、システムのシャットダウンや複数のセンサー情報は表示されません

Views:
13
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009232455</a>
Specialty:
hw
Last Updated:

環境

FAS500F

問題

  • node-02でIOM12Eモジュールの障害が検出され、node-01からのテイクオーバーが検出されます。

EMSログ

</LR>
<LR d="09Jul2022 07:22:00" n="node-01" t="1657318920" id="1655365394/8541" p="0" s="Ok" o="monitor" vf="" type="0" seq="75705">
<monitor_globalStatus_critical_1
     problem="This node has taken over node-02. "/>
</LR>
<LR d="09Jul2022 07:22:11" n="node-01" t="1657318931" id="1655365394/8542" p="3" s="Ok" o="dsa_worker0" vf="" type="0" seq="75706">
<ses_status_electronicsWarn_1
     prodChannel="NS224NSM8E (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0s"
     typeText="SES electronics"
     electrNumber="2"
     warningMsg="communication error"
     warningText="; enclosure services hardware failed"
     locationText="This element is on the rear of the shelf at the bottom, on shelf module (B)"/>
</LR>
<LR d="09Jul2022 07:22:11" n="node-01" t="1657318931" id="1655365394/8543" p="1" s="Ok" o="dsa_worker0" vf="" type="0" seq="75707">
<ses_status_ModuleError_1
     prodChannel="NS224NSM8E (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0s"
     moduleType="PCI switch"
     typeText="PCI Switch"
     ModuleNumber="2"
     errorMsg="status not available"
     errorText="; status not available"
     locationText="This element is on the rear of the shelf at the bottom, on shelf module (B)"/>

  • テイクオーバーの完了後na、ノード02のBMC CLIのIPMIセンサーが「」ステータスを表示してブートできませんでした。

SP-latest-IPMI:

=================== sensor ==========================
Sensor name    | reading   | unit     | status| lnr     | lcr     | lnc     | unc     | ucr     | unr
PVCCIN_CPU_FD   | na     | Volts    | na  | na    | 0.490    | 0.784    | 2.195    | 2.391    | na
PVCCSA_CPU_FD   | na     | Volts    | na  | na    | 0.297    | 0.396    | 1.485    | 1.683    | na
PVDDQ_AB_FD    | na     | Volts    | na  | na    | 0.488    | 0.799    | 1.482    | 1.697    | na
PVDDQ_CD_FD    | na     | Volts    | na  | na    | 0.488    | 0.799    | 1.482    | 1.697    | na
PVNN_PCH_AFD    | na     | Volts    | na  | na    | 0.268    | 0.474    | 1.175    | 1.216    | na
P0V9_PLX0_F    | na     | Volts    | na  | na    | 0.293    | 0.741    | 1.190    | 1.248    | na
P0V9_PLX1_F    | na     | Volts    | na  | na    | 0.293    | 0.741    | 1.190    | 1.248    | na
P3V_BAT      | na     | Volts    | na  | na    | 2.340    | 2.652    | 3.276    | 3.354    | na

 


Bat_Dstg_Cycles  | na     | cycles    | na  | na    | 2.000    | 5.000    | na    | na    | na
Bat_Cycle_Cnt   | na     | cycles    | na  | na    | na    | na    | na    | na    | na
Bat_Power_Fault  | na     | discrete   | na  | na    | na    | na    | na    | na    | na
Bat_Dsg_FET_Flt  | na     | discrete   | na  | na    | na    | na    | na    | na    | na
Bat_Chg_FET_Flt  | na     | discrete   | na  | na    | na    | na    | na    | na    | na
Bat_Pack_Invalid | na     | discrete   | na  | na    | na    | na    | na    | na    | na
Bat_Lrn_Active   | na     | discrete   | na  | na    | na    | na    | na    | na    | na
FRU Presence    | na     | discrete   | na  | na    | na    | na    | na    | na    | na

 

  • BMCから障害ノード-02の電源を再投入しますが、ブートできません。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.