すべてのノードでクラスタネットワークデグレードCRCエラーが検出されました
環境
クラスタネットワークスイッチCisco Nexus C3232C(NXOSバージョン7.0(3) i7(6)を実行)
問題
- ハードウェアエラー、パケット損失の続き、クラスタネットワークのデグレードが発生したことを示すすべてのノードのレポート:
[node_name-01: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e3b on node node_name-01 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).
[node_name-01: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e3a on node node_name-01 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).
[node_name-01: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif node_name-01_clus2 (node node_name-01) to cluster lif node_name-05_clus1 (node node_name-05).
[node_name-01: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif node_name-01_clus1 (node node_name-01) to cluster lif node_name-02_clus2 (node node_name-02).
[node_name-01: vifmgr: callhome.clus.net.degraded:alert]: Call home for CLUSTER NETWORK DEGRADED: Large MTU Packet Loss - Ping failures detected between node_name-01_clus2 ( 169.254.181.156 ) on node_name-01 and node_name-02_clus1 ( 169.254.162.103 ) on node_name-02
[node_name-02: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif node_name-02_clus1 (node node_name-02) to cluster lif node_name-05_clus1 (node node_name-05).
[node_name-02: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif node_name-02_clus2 (node node_name-02) to cluster lif node_name-01_clus1 (node node_name-01).
[node_name-02: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e3a on node node_name-02 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).
[node_name-02: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e3b on node node_name-02 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).
[node_name-02: vifmgr: callhome.clus.net.degraded:alert]: Call home for CLUSTER NETWORK DEGRADED: CRC Errors Detected - High CRC errors detected on port e3a node node_name-02
[node_name-04: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e3a on node node_name-04 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).
[node_name-04: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e3b on node node_name-04 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).
[node_name-04: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif node_name-04_clus1 (node node_name-04) to cluster lif node_name-05_clus1 (node node_name-05).
[node_name-04: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif node_name-04_clus2 (node node_name-04) to cluster lif node_name-01_clus1 (node node_name-01).
[node_name-04: vifmgr: callhome.clus.net.degraded:alert]: Call home for CLUSTER NETWORK DEGRADED: CRC Errors Detected - High CRC errors detected on port e3a node node_name-04
[node_name-05: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e3a on node node_name-05 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).
[node_name-05: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e3b on node node_name-05 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).
[node_name-05: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif node_name-05_clus1 (node node_name-05) to cluster lif node_name-04_clus1 (node node_name-04).
[node_name-05: vifmgr: vifmgr.cluscheck.ctdpktloss:alert]: Continued packet loss when pinging from cluster lif node_name-05_clus2 (node node_name-05) to cluster lif node_name-01_clus1 (node node_name-01).
[node_name-05: vifmgr: callhome.clus.net.degraded:alert]: Call home for CLUSTER NETWORK DEGRADED: Large MTU Packet Loss - Ping failures detected between node_name-05_clus1 ( 169.254.20.13 ) on node_name-05 and node_name-02_clus1 ( 169.254.162.103 ) on node_name-02
- 適用されたリファレンス構成ファイルにネットアップ構成が含まれていません:
switch-01# show running-config
!Command: show running-config
!No configuration change since last restart
!Time: Thu Jan 26 17:48:50 2023
version 7.0(3)I7(6) Bios:version 08.38
...
vlan 1
vrf context management
ip route 0.0.0.0/0 172.29.1.1
interface Ethernet1/1
interface Ethernet1/2
interface Ethernet1/3
...
interface Ethernet1/34
...