ACP 通信が SP によって切断されたため、「 shelf_fault 」と表示されます
環境
- ONTAP 9
- サービス プロセッサ(SP)
- Baseboard Management Controller(BMC)
問題
- システムは次のエラーを報告し、自動的に回復します。
Fri Apr 24 13:40:15 JST [node: dsa_worker1: ses.status.ACPError:alert]: DS4246 (S/N xxxxxxxxxx) shelf 0 on channel 0a ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the bottom center, on shelf module B.
Fri Apr 24 13:40:24 JST [node: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
Fri Apr 24 13:40:24 JST [node: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
Fri Apr 24 14:35:24 JST [node: dsa_worker5: ses.status.ACPInfo:info]: DS4246 (S/N xxxxxxxxxx) shelf 0 on channel 0b ACP Processor information for SAS shelf ACP processor 2: normal status.
Fri Apr 24 14:35:33 JST [node: statd: monitor.shelf.fault.ok:notice]: Fault previously reported on disk storage shelf attached to channel 0a has been corrected.
Fri Apr 24 14:36:00 JST [node: monitor: monitor.globalStatus.ok:notice]: The system's global status is normal.
- 次のレコードがから見つかり
SP-LATEST-SYSTEM-EVENT-LOG
ます。
Record 1771: Fri Apr 24 05:33:18 2020 [SP.critical]: Rebooting SP due to loss of ACP comms