メインコンテンツまでスキップ

ヘルスモニタがスイッチが停止していることを通知します。SwitchIfIslandWarm_Alert

Views:
10
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

環境

Cisco 3132Q-Vクラスタネットワークスイッチ

問題

  • スイッチ-02(クラスタスイッチ)が機能していません。すべてのトラフィックはSwitch-01で処理されます
  • ヘルスモニタのアラートがAutoSupport 経由で送信されます

Mar 17, 2022 08:29:08 CET HA Group Notification (Health Monitor process cshm: SwitchIfIslDownWarn_Alert[Switch-02 (xxxx)/Ethernet1/31]) ALERT

  • EMS-LOG-FILE AutoSupport のセクションで、次の手順を実行します。
Tue Mar 15 16:25:13 CET [Node-05: cshmd: hm.alert.raised:alert]: Alert Id = SwitchIfIslDownWarn_Alert , Alerting Resource = Switch-02(xxxx)/port-channel1 raised by monitor cluster-switch 
  • スイッチログ# show tech-support():

2022 Mar 15 16:21:07 Switch-02 %DIAG_PORT_LB-2-REWRITE_ENGINE_LOOPBACK_TEST_FAIL: Module:1
Test:RewriteEngine Loopback failed 10 consecutive times.
Faulty module:  Error:Loopback test failed. Packets lost on the SUP in the receive direction

2022 Mar 15 16:21:07 Switch-02 %DIAGCLIENT-2-EEM_ACTION_HM_SHUTDOWN: Test <RewriteEngineLoopback>
has been disabled as a part of default EEM action

2022 Mar 15 16:21:07 Switch-02 %MODULE-4-MOD_WARNING: Module 1 (Serial number: xxxxx) reported warning due to Loopback test failed.
Packets lost on the SUP in the receive direction in device DEV_SUPERVISOR_CTRL (device error 0x41830059)

2022 Mar 15 16:21:07 Switch-02 %VSHD-5-VSHD_SYSLOG_CONFIG_I: Configured from vty by admin on vsh.bin.4635

  • スイッチコマンド # show module

Switch-02# show module
Mod  Ports             Module-Type        Model                 Status

---- ----------------- -----------------  --------------------- ---------
1    32                32x40G Supervisor  N3K-C3132Q-V          active *

Mod  Sw                Hw     Slot
---  ----------------  ------ ----
1    7.0(3)I6(1)       1.0    NA

Mod  MAC-Address(es)                         Serial-Num
---  --------------------------------------  ----------
1    d4-xx-xx-xx-xx-xx to d4-xx-xx-xx-xx-xx  xxxx

Mod  Online Diag Status
---  ------------------
1    Fail

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.