メインコンテンツまでスキップ

nv.partner-size.mismatch アラートが発生します

Views:
32
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2008704045</a>
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • FAS/AFF

問題

  • 両方のノードで「 cf.rv.notConnected" 」と「 nv.partner.sizemismatch 」が発生します。
  • 以下の EMS ログレポート

例:

[?] Sun Mar 21 05:04:58 +0900 [Node-1: raidio_thread: nvmm.mirror.aborting:debug]: mirror of sysid 1, partner_type HA Partner and mirror state MIRROR_ONLINE is aborted because of reason Abort Pending.
[?] Sun Mar 21 05:04:58 +0900 [Node-1: nvram_sync: nvmm.mirror.offlined:debug]: params: {'mirror': 'HA Partner Mirror Offlined'}
[?] Sun Mar 21 05:04:58 +0900 [Node-1: rendezvous_proc: cf.rv.notConnected:alert]: HA interconnect: Connection for 'cfo_rv' failed.
[?] Sun Mar 21 05:04:58 +0900 [Node-1: nic_mgr: cf.nm.nicViError:info]: HA interconnect: NIC 0 has an error on RAID VI (virtual interface #9): SEND_DESC_TIMEOUT 12.
[?] Sun Mar 21 05:04:58 +0900 [Node-1: nic_mgr: cf.nm.nicReset:notice]: HA interconnect: Initiating soft reset on card 0 due to rendezvous reset.
[?] Sun Mar 21 05:04:59 +0900 [Node-1: cf_firmware: cf.fm.partnerFwTransition:info]: params: {'progresscounter': '0', 'newstate': 'SF_UNKNOWN', 'prevstate': 'SF_UP'}
[?] Sun Mar 21 05:04:59 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of Node-1 by Node-2 disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).

[?] Sun Mar 21 05:05:01 +0900 [Node-1: nvram_sync: nvmm.mirror.disabled:debug]: params: {'mirror': 'HA Partner Mirror Disabled'}
[?] Sun Mar 21 05:05:01 +0900 [Node-1: nvram_sync: nv.partner.size.mismatch:alert]: CF monitor: NVRAM size mismatch between nodes detected; node requires 661651456 bytes, partner exported 0 bytes.
[?] Sun Mar 21 05:05:02 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of Node-1 by Node-2 disabled (NVRAM size mismatch).
[?] Sun Mar 21 05:05:05 +0900 [Node-1: cf_main: cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of Node-2 disabled (NVRAM size mismatch).

  • エラーが自動的に回復します。

例:

[?] Sun Mar 21 05:05:05 +0900 [Node-1: rv_assist_proc: ems.engine.suppressed:debug]: Event 'cf.rv.flush.handleExchange' suppressed 2 times in last 2809539 seconds.
[?] Sun Mar 21 05:05:05 +0900 [Node-1: rv_assist_proc: cf.rv.flush.handleExchange:info]: HA interconnect: Flushing is active.
[?] Sun Mar 21 05:05:06 +0900 [Node-1: rv_assist_proc: nvmm.mirror.enabled:debug]: params: {'mirror': 'HA Partner Mirror Enabled'}
[?] Sun Mar 21 05:05:06 +0900 [Node-1: rendezvous_proc: cf.rv.connected:info]: HA interconnect: Connection for 'cfo_rv' succeeded.
[?] Sun Mar 21 05:05:06 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of Node-1 by Node-2 disabled (unsynchronized log).
[?] Sun Mar 21 05:05:06 +0900 [Node-1: cf_firmware: cf.fm.partnerFwTransition:info]: params: {'progresscounter': '2816232', 'newstate': 'SF_UP', 'prevstate': 'SF_UNKNOWN'}
[?] Sun Mar 21 05:05:07 +0900 [Node-1: cf_main: cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of Node-2 disabled (unsynchronized log).
[?] Sun Mar 21 05:05:12 +0900 [Node-1: nvram_sync: nvmm.mirror.onlined:debug]: params: {'mirror': 'HA Partner Mirror Onlined'}
[?] Sun Mar 21 05:05:12 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerEnabled:notice]: Failover monitor: takeover of Node-1 by Node-2 enabled

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support

 

  • この記事は役に立ちましたか?