メインコンテンツまでスキップ

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

nv.partner-size.mismatch アラートが発生します

Views:
40
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2008704045</a>
Specialty:
hw
Last Updated:

環境

  • ONTAP 9
  • FAS/AFF

問題

  • 両方のノードで「 cf.rv.notConnected" 」と「 nv.partner.sizemismatch 」が発生します。
  • 以下の EMS ログレポート

例:

[?] Sun Mar 21 05:04:58 +0900 [Node-1: raidio_thread: nvmm.mirror.aborting:debug]: mirror of sysid 1, partner_type HA Partner and mirror state MIRROR_ONLINE is aborted because of reason Abort Pending.
[?] Sun Mar 21 05:04:58 +0900 [Node-1: nvram_sync: nvmm.mirror.offlined:debug]: params: {'mirror': 'HA Partner Mirror Offlined'}
[?] Sun Mar 21 05:04:58 +0900 [Node-1: rendezvous_proc: cf.rv.notConnected:alert]: HA interconnect: Connection for 'cfo_rv' failed.
[?] Sun Mar 21 05:04:58 +0900 [Node-1: nic_mgr: cf.nm.nicViError:info]: HA interconnect: NIC 0 has an error on RAID VI (virtual interface #9): SEND_DESC_TIMEOUT 12.
[?] Sun Mar 21 05:04:58 +0900 [Node-1: nic_mgr: cf.nm.nicReset:notice]: HA interconnect: Initiating soft reset on card 0 due to rendezvous reset.
[?] Sun Mar 21 05:04:59 +0900 [Node-1: cf_firmware: cf.fm.partnerFwTransition:info]: params: {'progresscounter': '0', 'newstate': 'SF_UNKNOWN', 'prevstate': 'SF_UP'}
[?] Sun Mar 21 05:04:59 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of Node-1 by Node-2 disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).

[?] Sun Mar 21 05:05:01 +0900 [Node-1: nvram_sync: nvmm.mirror.disabled:debug]: params: {'mirror': 'HA Partner Mirror Disabled'}
[?] Sun Mar 21 05:05:01 +0900 [Node-1: nvram_sync: nv.partner.size.mismatch:alert]: CF monitor: NVRAM size mismatch between nodes detected; node requires 661651456 bytes, partner exported 0 bytes.
[?] Sun Mar 21 05:05:02 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of Node-1 by Node-2 disabled (NVRAM size mismatch).
[?] Sun Mar 21 05:05:05 +0900 [Node-1: cf_main: cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of Node-2 disabled (NVRAM size mismatch).

  • エラーが自動的に回復します。

例:

[?] Sun Mar 21 05:05:05 +0900 [Node-1: rv_assist_proc: ems.engine.suppressed:debug]: Event 'cf.rv.flush.handleExchange' suppressed 2 times in last 2809539 seconds.
[?] Sun Mar 21 05:05:05 +0900 [Node-1: rv_assist_proc: cf.rv.flush.handleExchange:info]: HA interconnect: Flushing is active.
[?] Sun Mar 21 05:05:06 +0900 [Node-1: rv_assist_proc: nvmm.mirror.enabled:debug]: params: {'mirror': 'HA Partner Mirror Enabled'}
[?] Sun Mar 21 05:05:06 +0900 [Node-1: rendezvous_proc: cf.rv.connected:info]: HA interconnect: Connection for 'cfo_rv' succeeded.
[?] Sun Mar 21 05:05:06 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of Node-1 by Node-2 disabled (unsynchronized log).
[?] Sun Mar 21 05:05:06 +0900 [Node-1: cf_firmware: cf.fm.partnerFwTransition:info]: params: {'progresscounter': '2816232', 'newstate': 'SF_UP', 'prevstate': 'SF_UNKNOWN'}
[?] Sun Mar 21 05:05:07 +0900 [Node-1: cf_main: cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of Node-2 disabled (unsynchronized log).
[?] Sun Mar 21 05:05:12 +0900 [Node-1: nvram_sync: nvmm.mirror.onlined:debug]: params: {'mirror': 'HA Partner Mirror Onlined'}
[?] Sun Mar 21 05:05:12 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerEnabled:notice]: Failover monitor: takeover of Node-1 by Node-2 enabled

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Scan to view the article on your device